- Home
- Search Results
- Page 1 of 1
Search for: All records
-
Total Resources2
- Resource Type
-
0000000002000000
- More
- Availability
-
11
- Author / Contributor
- Filter by Author / Creator
-
-
Andriolo, Jessica M. (1)
-
Benton, Kendall (1)
-
Grumstrup, Erik M (1)
-
Grumstrup, Erik M. (1)
-
Hollinbeck, Skyler (1)
-
Orcutt, Emma (1)
-
Orcutt, Emma K. (1)
-
Peterson, Zöe C. (1)
-
Skinner, Jack L. (1)
-
Varapragasam, Shelton J. (1)
-
#Tyler Phillips, Kenneth E. (0)
-
#Willis, Ciara (0)
-
& Abreu-Ramos, E. D. (0)
-
& Abramson, C. I. (0)
-
& Abreu-Ramos, E. D. (0)
-
& Adams, S.G. (0)
-
& Ahmed, K. (0)
-
& Ahmed, Khadija. (0)
-
& Aina, D.K. Jr. (0)
-
& Akcil-Okan, O. (0)
-
- Filter by Editor
-
-
& Spizer, S. M. (0)
-
& . Spizer, S. (0)
-
& Ahn, J. (0)
-
& Bateiha, S. (0)
-
& Bosch, N. (0)
-
& Brennan K. (0)
-
& Brennan, K. (0)
-
& Chen, B. (0)
-
& Chen, Bodong (0)
-
& Drown, S. (0)
-
& Ferretti, F. (0)
-
& Higgins, A. (0)
-
& J. Peters (0)
-
& Kali, Y. (0)
-
& Ruiz-Arias, P.M. (0)
-
& S. Spitzer (0)
-
& Sahin. I. (0)
-
& Spitzer, S. (0)
-
& Spitzer, S.M. (0)
-
(submitted - in Review for IEEE ICASSP-2024) (0)
-
-
Have feedback or suggestions for a way to improve these results?
!
Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
Although similar to more commonly implemented single wavelength approaches, broadband pump‐probe or transient absorption microscopy presents unique experimental challenges due to the simultaneous requirements of a broadband probe pulse and a small sample volume. Here we provide an in‐depth analysis of broadband detection schemes and their common noise sources to provide strategies for balancing the conflicting needs of high sensitivity and low probe fluence. We show that broadband pump‐probe microscopy is atypically sensitive to laser shot noise and therefore, low pump on/off modulation frequencies, on the order of 100 s of Hz to a few kHz, are essential to measure small (~10^-3 - 10^-4) amplitude transient spectra while remaining in the perturbative limit.more » « lessFree, publicly-accessible full text available November 6, 2026
-
Orcutt, Emma K.; Varapragasam, Shelton J.; Peterson, Zöe C.; Andriolo, Jessica M.; Skinner, Jack L.; Grumstrup, Erik M. (, ACS Applied Materials & Interfaces)
An official website of the United States government
